TM 10-7360-226-13&P
CONTAINERIZED KITCHEN (WITH TRAILER)
TROUBLESHOOTING PROCEDURES (ELECTRICAL SYSTEM)
THIS WORK PACKAGE COVERS:
Electrical System
INITIAL SETUP:
Kitchen set up
Maintenance Level
Operator/Crew
ELECTRICAL SYSTEM MALFUNCTIONS
Table 1. Troubleshooting Procedures (Electrical System)
Malfunction
Test or Inspection
Corrective Action
No power to kitchen
EXTERNAL POWER AVAILABLE
Ensure that the external power
external source
indicator (Main Control Panel) is
cable is properly connected
not lit
(Power Entrance Panel)
Ensure that the power cable is
connected to the source and
the source is energized
Ensure that the external power
control circuit breaker (Power
Entrance Panel) is closed
(pushed in)
Notify unit maintenance
EXTERNAL POWER AVAILABLE
Press the EXTERNAL POWER
indicator is lit, EXTERNAL POWER pushbutton (Main Control
indicator is not lit
Panel)
Notify unit maintenance
EXTERNAL POWER AVAILABLE
Check/reset the input power
indicator is lit and EXTERNAL
circuit breaker (#1 on Power
POWER indicator is lit
Distribution Panel)
Notify unit maintenance
No power to kitchen
Check/close the AC CIRCUIT
generator source
GENERATOR POWER
INTERRUPTER switch
AVAILABLE indicator is not lit
0010 00-1