TM 10-7360-226-13&P
0010 00
CONTAINERIZED KITCHEN (WITH TRAILER)
TROUBLESHOOTING PROCEDURES (ELECTRICAL SYSTEM)
Table 1. Troubleshooting Procedures (Electrical System) - Continued
Malfunction
Test or Inspection
Corrective Action
Refill fuel tank
Check for dirty fuel filter/water
Service fuel filter/water
separator
separator (Refer to TM 9-6115-
642-10)
Check air cleaner restriction
Service air cleaner assembly
indicator for indication of a clogged
(Refer to TM 9-6115-642-10)
air cleaner (inside access door by
cook center)
Ambient temperature below 40oF
control panel) to PREHEAT for
no more than 30 seconds
before cranking engine. Refer
to TM 9-6115-642-10
Notify unit maintenance
Interior lights do not
No other electrical components
See "No Power to Kitchen"
work
operate
All other electrical components
Check/reset lighting circuit
operate
breaker (#19 on Power
Distribution Panel)
Notify unit maintenance
No power at one or
No other electrical components
See "No Power to Kitchen"
operate
All other electrical components
Check/reset ground fault
operate properly
interrupter (on receptacle next
to spice rack)
Notify unit maintenance
END OF WORK PACKAGE
0010 00-3/4 Blank