TM 10-7360-226-13&P
CONTAINERIZED KITCHEN (WITH TRAILER)
TROUBLESHOOTING PROCEDURES (HAND SINK ASSEMBLY)
THIS WORK PACKAGE COVERS:
Hand Sink Assembly
INITIAL SETUP:
CK set up
Maintenance Level
Operator/Crew
HAND SINK ASSEMBLY MALFUNCTIONS
Table 1. Troubleshooting Procedures (Hand Sink Assembly)
Malfunction
Test or Inspection
Corrective Action
No hot or cold water
Water pump running
Immediately turn water heater
OFF (appliance control box)
Check hoses for kinks,
Remove kinks, tighten loose or
obstructions, leaks, missing
leaking fittings, repair/replace
washers
damaged hose
Supply valve from tank trailer open
Check/open valve
Notify unit maintenance
Pump will not run
Immediately turn water heater
OFF (appliance control box)
Check/plug in pump power cord
Verify pump switch is ON
(appliance control box)
Verify appliance control box is
plugged in
Check/reset pump circuit
breaker (appliance control box)
Check/reset appliance control
box circuit breaker (#24 on
Power Distribution Panel)
Notify unit maintenance
Low water pressure
Check hoses for kinks,
Remove kinks, tighten loose or
obstructions, leaks, missing
leaking fittings, replace
washers
damaged hose
Supply valve from tank trailer open
Check/open valve
0013 00-1