Interval
Procedure
Not Fully Mission Capable If:
Item No
Item to
Check/Service
Arming Pin
Inspect lanyard (1) for three inch Lanyard (1) is not present or
Assembly
loop of type III nylon cord.
not serviceable. Knob (2) is
(Removed)
Inspect knob (2) for cracks,
cracked. Swedge (3) is not
chips. Inspect swedge (3) for
secure or upper portion of
proper attachment. Ensure no
cable (4) has broken strands.
strands of upper cable (4) are
Cable (4) is not visible in
broken. Look for cable in
inspection hole (5). Knurled
inspection hole (5). Inspect
nut (6) is cracked or missing
knurled nut (6) for cracks and
stud. Spring (7) is corroded
ensure two studs are present.
or lacks tension. Lower
Ensure spring (7) for proper
portion of cable (4) has
tension and lack of corrosion.
broken strands, is not secure
Inspect lower portion of cable (4) to swedge, or is not visible
for broken strands and ensure
thru inspection hole (8).
cable is visible through
Arming pin (9) is not
inspection hole (8) in arming pin
straight. Arming pin guide
(9). Inspect arming pin (9) for
bush (10) is not properly
straightness. Inspect arming pin seated. Arming pin guide
guide bush (10) is properly
bush seal (11) is not present
seated and tight. Ensure arming or not serviceable.
pin guide bush seal (11) is
present and serviceable
2-8