TM 10-1670-300-20&P
TO 14D1-2-469-2
NAVAIR 13-1-42
Location
Interval
Procedure
Not Fully Mission Capable If:
Item No
Item to
Check/Service
FF-2 Release
Inspect withdrawal hook (1) for
Withdrawal hook (1) gap is
(LOADED)
proper gap. Inspect withdrawal
too large or too small. Cable
Power Cable
hook retainer clamp (2) for
does not portrude thru
Assembly &
minimum 0.1 inch cable
withdrawal hook retainer
Frangible Cap
portuding. Inspect withdrawal
clamp (2) 1/16-inch
hook retainer clamp knurled nut
withdrawal hook retainer
(3) and rubber pad (4) for
clamp knurled nut (3) or
damage. There must be at least
rubber pad (4) is damaged.
three threads of knurled nut
Exposed power cable (5) has
exposed. Inspect exposed power broken strands. Rectangular
cable (5) for broken strands.
key (6) is offset or canted
Ensure rectangular key (6) is not more than 15 degrees. Power
offset or canted more than 15
cable housing (7) is damaged
degrees. Inspect power cable
Power cable housing knurled
housing (7) for damage (broken
nut (8) is damaged.
strands of armor cable). Ensure
Frangible cap (9) is cracked
power cable housing knurled nut
or corroded. Rubber buffer
(8) is properly seated. Remove
(10) is damaged or has dry
frangible cap (9) and inspect for
rot. Power cable lock nut (11)
cracks and corrosion. Ensure
is not 7/16-inch or is not
there are no marks or tapes
serviceable. Threadless
placed on frangible cap (9).
washer (12) is not present or
Inspect rubber buffer (10) for dry serviceable. Hole (14) in
rot, cracks. Ensure power cable
power cable rod (13) is
lock nut (11) is 7/16-inch and
oblong.
properly seated and securely
fastened to power cable rod.
Ensure threadless washer (12) is
present. Inspect power cable rod
(13) to ensure that hole (14) is
round NOT oblong
2-9