2-35. WATER HEATER ELECTRIC CONTROL ASSEMBLY (CONT)
REPAIR (Cont)
(2)
To remove fuel supply control assembly (2), disconnect fuel line couplings (3 and 4), disconnect
coupling (5), remove two screws (6) and two washers (7). Remove fuel supply control assembly by pulling fuel solenoid
wires out of conduit (5).
(3)
To disconnect fuel line (3), disconnect coupling at adapter (8) and remove fuel line. Unscrew adapter
(8) from burner head (9).
(4)
To disconnect fuel line (4), disconnect coupling at elbow (10). Unscrew elbow (10) from fuel pump
(11).
Change 1 2-124.5