TM 10-3510-209-243-23. WATER HEATER OPERATING LIMIT AND HIGH-LIMIT CONTROLSThis task covers:a. Replacementb. AdjustmentINITIAL SETUP:ToolsGeneralSafetyInstructionsGeneral mechanic's tool setSC 5180-90WARNINGPersonnelRequiredHigh voltage is present on this equipment.Do not perform maintenance with power on.MOS 63J (1)Death or serious injury may result.Materials/PartsWARNINGOperating/high limit relayEnsure water heater is cold before servicingThread sealer compoundthe high-limit temperature control. The(Item 5, App C)water vessel becomes hot during operationand burns or bodily injury may result fromcontact with the water heater before itcools. Allow water heater to cool beforeservicing the high-limit temperature control.EquipmentConditionTM 10-3510-209-10, Tarp assembly removed.REPLACEMENT1.Remove cap (1), retainer (2), and cover plate (3) from high-limit control (4).2.Tag and disconnect two wires (5).3.Loosen conduit nut (6) on each end of conduit (7) and slide nuts toward center of conduit.4.Open inspection plate (8) and pull wires until wires do not extend beyond end of conduit (7).3-108