3-23. WATER HEATER OPERATING LIMIT AND HIGH-LIMIT CONTROLS (CONT)
REPLACEMENT (Cont)
5.
Push conduit (7) to the right while turning high-
limit control (4) counterclockwise until control is
clear of manifold. Remove limit control from
manifold by continuing to turn counterclockwise.
6.
Remove nut (9) and remove raintight connector
(10).
NOTE
Before installing the replacement
high-limit control (4), coat threads
with thread sealer compound (Item 5,
App C).
7.
Install raintight connector (10) and nut (9) in
high-limit control (4).
8.
Install high-limit control (4) in manifold and turn
clockwise. On last turn insert end of conduit (7)
into control housing and push conduit into
housing.
9.
Install conduit nuts (6) on raintight connectors
(10).
10.
Pull two wires (5) out of end of conduit (7).
Connect wires and remove tags.
11.
Close inspection plate (8).
12.
Install cover plate (3) on high-limit control (4)
and install retainer (2) and cap (1).