TM 10-3510-209-24
Table 2-2. Unit Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
28.
DRYER FLAME PULSATES.
Step 1.
Check for improper air shutter adjustment. Exhaust gases should be
clear or light gray.
a.
If exhaust gas is dark, adjust air shutter. Refer to
TM 10-3510-209-10.
b.
If exhaust gas is proper color, proceed to next step.
Step 2.
Check for low fuel supply in fuel container.
a.
If container is low on fuel, fill container with fuel. Refer to
TM 10-3510-209-10.
b.
If container fuel level is correct, proceed to next step.
Step 3.
Check for water in fuel by draining a small amount of fuel into a
clear container. Look for fuel/water separation.
a.
If fuel/water is present, drain fuel supply and refill with
proper fuel. Refer to TM 10-3510-209-10.
b.
If water is not present, proceed to next step.
Step 4.
Check for dirty burner assembly.
a.
If burner is dirty, clean burner assembly. Refer to
paragraph 2-42.
b.
If burner is serviceable and problem persists, notify your
supervisor.
29.
EXCESSIVE SMOKE FROM DRYER EXHAUST.
Step 1.
Check for improper adjustment of air shutter. Exhaust gases should
be light gray or clear.
a.
If exhaust is too dark, adjust air shutter. Refer to
TM 10-3510-209-10.
b.
If exhaust is proper color, proceed to next step.
2-46