Table 2-2. Unit Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
34.
WASHER FILL LEVEL IS TOO LOW. (Cont)
Step 3.
Check for inoperative water level switch. With power off, remove
switch cover and perform continuity check with switch in both
positions.
a.
If switch is defective, replace water level switch.
(1) Remove screw (1) and cover (2) from switch box (3).
(2) Tag and disconnect wires (4) from defective high level
switch (5) or low level switch (6).
NOTE
Both high level switch (5) and low level switch (6) are removed and replaced the
same way. This procedure will cover the replacement of just one switch.
(3) Remove two screws (7) and defective switch (5).
NOTES:
CONDUIT AND
WIRES REMOVED
FROM SWITCH BOX
FOR CLARITY.