TM 10-3510-209-24
Table 2-2. Unit Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
33.
WASHER WILL NOT FILL AND CYLINDER WILL NOT ROTATE. (Cont)
(6) Position new
switch (7) on
mounting bracket
(14) and install
two allen head
screws (10),
lockwashers
(11), plate
(12), and two
nuts (13).
(7) Install wires in
housing of
switch (7) and
install conduit
nut (8) on elbow
(9).
(8) Connect wires (5) and (6) to switch (7) and remove tags.
Install two screws (3).
(9) Connect wires (4) to switch top (2).
(10) Install switch top (2) and two screws (1).
b.
If switch is serviceable and problem persists, notify your
supervisor.
34.
WASHER FILL LEVEL IS TOO LOW.
Step 1.
Check for improperly adjusted water level control float. Low water
level should be approximately 7 inches (17.8 cm) measured from bottom
of cylinder.
a.
If level is incorrect, adjust water level control float.
Refer to paragraph 2-20.
b.
If level is proper, proceed to next step.
Step 2.
Check for stuck water level control float.
a.
If control float is stuck, clean obstruction.
b.
If control float is not stuck, proceed to next step.
2-50