TM 10-3510-220-24
3-17. EXTRACTOR CONTROL BOX (CONT)
REPAIR
1.
Remove and replace lid safety switch and/or solenoid safety switch.
WARNING
High voltage is present on this equipment. Do not perform
maintenance with power on. Death or serious injury may result.
WARNING
Failure to adjust the lid safety switch and/or solenoid safety switch
could result in injury to personnel.
a.
Set extractor circuit breaker to the
OFF position.
b.
Remove twelve screws (1),
lockwashers (2), and extractor
control panel cover (3).
NOTE
A record of wire removal is needed so that
installation of wires on the replacement
switch is exactly duplicated.
c.
d.
e.
f.
g.
h.
Tag and disconnect electrical wires
(17) from lid safety switch (19).
Remove two screws (10) and lid
safety switch (19).
Install lid safety switch (19) and two
screws (10).
Connect wires (17) to lid safety
switch (19). Remove tags.
Refer to ADJUSTMENT, step 2, and
adjust lid safety switch (19).
Install twelve screws (1),
lockwashers (2), and extractor
control panel cover (3).
3-77