TM 10-3510-220-24
3-17. EXTRACTOR CONTROL BOX (CONT)
ADJUSTMENT (Cont)
f.
If lid safety switch (9) cannot be pressed, perform the following:
(1) Loosen two screws (10) that secure lid safety switch (9).
(2) Adjust lid safety switch (9) against lid safety cam (8) until switch is pressed.
(3) Tighten two screws (10) securing lid safety switch (9).
(4) Repeat steps e and f until safety switch (9) is pressed.
g.
Tighten lid safety cam screw (7).
h.
Install extractor control panel cover (3), twelve lockwashers (2), and screws (1). Set
extractor circuit breaker in power panel to the ON position.
WARNING
Keep clear of the extractor basket when
checking operation of the lid safety switch.
i.
Open lid and try to start extractor to
ensure unit does not operate with lid
open. Refer to TM 10-3510-220-10.
3.
Adjust solenoid safety switch.
WARNING
High voltage is present on this equipment.
Do not perform maintenance with power
on. Death or serious injury may result.
WARNING
Failure to properly adjust the lid safety
switch properly could result in injury to
personnel.
a.
Set extractor circuit breaker on
electrical panel to the OFF position.
3-74