TM 10-3510-220-24
3-17. EXTRACTOR CONTROL BOX(CONT)
ADJUSTMENT (Cont)
4.
Adjust lid lock lever.
a.
b.
c.
d.
e.
f.
WARNING
High voltage is present on this equipment. Do not perform
maintenance with power on. Death or serious injury may result.
Set extractor circuit breaker on electrical panel to the OFF position.
Remove twelve screws (1), lockwashers (2), and extractor control panel cover (3).
Loosen locknut (13) on the end of the
lid lock lever (14).
Rotate lid lock lever adjusting screw
(15) until it is within 1/16 inch (1.58
mm) of the face on the lid lock dam
(16). Tighten locknut (13).
Attempt to lift lid. Lid is properly
adjusted when gap between lid and
curb is no more than 1/2 inch (1 .27
mm) when closed and locked.
Install extractor control panel cover
(3), twelve lockwashers (2), and
screws (1).
Turn extractor circuit breaker in
power panel to ON.
3-76