TM 10--3510--221--24
0051 00--2
R2 TANK NOT HEATING FAULT -- Continued
0051 00
8. Check position of steam inlet valves (FV115A and B).
Are FV115A and B open?
YES Go to step 9.
NO Go to TYPICAL WATER CONTROL VALVE NOT OPENING/CLOSING FAULT (WP 0047 00).
9. Check position of inlet (FV104A and B) and outlet (FV105A and B) valves on rinse 2 tank.
Are valves open?
YES Go to step 10.
NO Go TYPICAL WATER CONTROL VALVE NOT OPENING/CLOSING FAULT (WP 0047 00) to
check suspect inlet or outlet valve.
10. Check for heat at outlet hose of both steam inlet valves.
Are both hoses hot?
YES Go to step 12.
NO Go to step 11.
11. Use EXAMINE INPUTS mode to check rinse 2 tank temperature (TE103) and condensate temperature
(TE201).
Is temperatures > 125 degrees F?
YES Go to step 12.
NO Go to CONDENSATE OR RECYCLED WATER TEMPERATURE LO FAULT (WP 0053 00).
12. Check for heat at water plumbing at outlet of steam eductor.
Is water plumbing hot?
YES Go to step 13.
NO Replace steam eductor on system that is not hot (WP 0149 00).
13. Observe operator panel A. When display reads BOILING DOWN THE STILL record time.
14. Continue to observe operator panel A.
Does display change to laundry cycle menu in < 25 minutes?
YES Return to normal operation.
NO Go to STILL NOT BOILING DOWN FAULT (WP 0062 00).
END OF WORK PACKAGE