TM 10--3510--221--24
0065 00--1
DISTILLATE PUMP DOES NOT TURN ON
0065 00
THIS WORK PACKAGE COVERS:
Troubleshooting Distillate Pump Does Not Turn On Fault
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
Power must be applied at main control
Multimeter (Item 2, WP 0272 00)
enclosure (WP 0010 00).
1. Use maintenance menu to turn on distillated pump (WP 0010 00).
Does pump come on?
YES Return to normal operation.
NO Go to step 2.
2. Position SW2 then SW1 to OFF.
3. Open door on main control enclosure.
4. Check distillate pump overload relay.
Is lever tripped?
YES Go to DISTILLATE PUMP OVERLOAD FAULT (WP 0055 00).
NO Go to step 5.
5. Check circuit breaker CB6.
Is CB6 tripped?
YES Reset CB6. Go to step 6.
NO Go to step 9.
6. Position SW1 then SW2 to ON.
7. Use maintenance menu to turn on distillate pump. Observe pump operation.
Does distillate pump come on?
YES Return to normal operation.
NO Go to step 8.
8. Check circuit breaker CB6.
Is CB6 tripped?
YES Check for shorted wire or connection between CB6, distillate pump contactor, and distillate
pump.
NO Go to step 10.
9. Position SW1 then SW2 to ON.