INSTALLATION
1. Install blower wheel (15) onto motor shaft (25).
2. Install tapered bushing (24) and key (28) onto motor shaft (25) to achieve previously recorded dimension.
3. Secure blower wheel (15) to tapered bushing (24) with three screws (26).
4. Position motor (5) with attached blower wheel (15) into blower duct (11) and mounting bracket (8). Align motor
(5) to marks on mounting bracket (8).
5. Install four screws (20), flat washers (21), lock washers (22), and nuts (23), but do not tighten.
6. Position end of blower wheel (15) to end of cone (16) at previously recorded dimension.
7. Secure motor with four screws (20), flat washers (21), lock washers (22), and nuts (23).
8. Install blower guide (19) into blower duct (11), then secure with four screws (17) and nuts (18).
9. Install cover plate (14) onto blower duct (11), then secure with four screws (12) and nuts (13).
10. Install outlet guard (10) into blower duct (11) then tighten two clamping knobs (9).
11. Remove two screws (1), then remove cover (2) and gasket (3) from junction box (4).
12. Insert conduit fitting (7) and wiring into junction box (4), then secure with conduit nut (6).
13. Connect wiring of motor (5) as tagged.
14. Install cover (2) and gasket (3) onto junction box (4), then secure with two screws (1).
15. Use maintenance menu to test blower rotation (WP 0010 00). Ensure blower rotates freely and smoothly.
END OF WORK PACKAGE