TM 10--3510--221--24
0132 00--1
OUTLET DAMPER AIR CYLINDER
REPLACEMENT
0132 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tags (Item 9, WP 0271 00)
Tape, Anti--Seizing (Item 10, WP 0271 00)
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
LADS power shut off at main control
enclosure (WP 0112 00).
Air pressure must be vented (WP 0113 00).
REMOVAL
1. Tag and disconnect air lines (1) from air cylinder (2).
NOTE
Step 2 applies to drum B only.
2. Remove six screws (3) and lock washers (4) then remove protective cover (5) from outlet duct (6).
3. Remove hair pin (7) from clevis pin (8).
4. Remove clevis pin (8) securing air cylinder (2) to link arm (9).
5. Remove hair pin (10) from clevis pin (11).
6. Remove clevis pin (11) securing air cylinder (2) to mounting bracket (12).
7. Remove air cylinder (2) from between link arm (9) and mounting bracket (12).
8. Extend piston (13). Measure and record distance from tip of rod adapter (14) to front end of air cylinder (2).
9. Loosen jam nut (15). Unthread rod adapter (14) and jam nut from piston (13).
10. Remove flow control valves (16) from air cylinder (2).
11. Clean anti--seizing tape from threads of flow control valves (16).