TM 10--3510--221--24
0131 00--1
INLET DAMPER AIR CYLINDER
REPLACEMENT
0131 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tags (Item 9, WP 0271 00)
Tape, Anti--Seizing (Item 10, WP 0271 00)
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
LADS power shut off at main control
enclosure (WP 0112 00).
Air pressure must be vented (WP 0113 00).
REMOVAL
1. Tag and disconnect air lines (1) from air cylinder (2).
2. Remove hairpins (3) from clevis pins (4) at both ends of air cylinder (2).
3. Remove clevis pins (4) securing air cylinder (2) to mounting pad (5) and inlet damper (6).
4. Remove air cylinder (2) from between mounting bracket (5) and inlet damper (6).
5. Extend piston (7). Measure and record distance from tip of rod adapter (8) to front end of air cylinder (2).
6. Loosen jam nut (9). Unthread rod adapter (8) and jam nut from piston (7).
7. Remove flow control valves (10) from air cylinder (2).
8. Clean anti--seizing tape from threads of flow control valves (10).