TM 10--3510--221--24
0150 00--1
WATER TEMPERATURE SENSOR
REPLACEMENT
0150 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Sealant, Pipe Thread (Item 6, WP 0271 00)
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
Water must be drained from rinse 2 tank
(WP 0114 00).
LADS power shut off at main control enclosure
(WP 0112 00).
REMOVAL
1. Disconnect electrical connector (1) from temperature sensor (2).
2. Loosen nut (3) then remove temperature sensor (2) from fitting (4).
3. Measure and record distance from tip of temperature sensor (2) to lower ferrule (5).
4. Unthread fitting (4) from rinse 2 tank (6).
5. Clean pipe sealant from threads of fitting (4).
6
4
5
7
3
2
1