TM 10--3510--221--24
0150 00--2
WATER TEMPERATURE SENSOR
REPLACEMENT -- Continued
0150 00
INSTALLATION
1. Connect electrical connector (1) to new temperature sensor (2).
2. Access examine inputs function using maintenance menu (WP 0010 00), then observe and record temperature
reading for TE100.
3. Access temperature sensor calibration function using maintenance menu (WP 0010 00), then set output of
temperature sensor TE103 to same temperature reading as recorded for TE100.
4. Slide nut (3), upper ferrule (7) and lower ferrule (5) onto temperature sensor (2).
5. Insert temperature sensor (2) into fitting (4) at previously recorded dimension.
6. Tighten nut (3) onto fitting (4) to swage lower ferrule (5) on temperature sensor (2).
7. Loosen nut (3) and remove temperature sensor (2) from fitting (4).
8. Apply pipe sealant to threads of fitting (4).
9. Thread fitting (4) into rinse 2 tank (6).
10. Insert temperature sensor (2) into fitting (4) then tighten nut (3).
11. Perform a FILL TANKS operation (TM 10--3510--221--10). When rinse 2 tank (6) is full visually check for water
leaks at fitting (4).
END OF WORK PACKAGE