TM 10--3510--221--24
0148 00--3/4 blank
STEAM INLET VALVE REPLACEMENT --
Continued
0148 00
INSTALLATION
1. Apply anti--seizing tape to elbows (2).
2. Install elbows (2) onto new actuator (6).
NOTE
When installing valve body, flats on stem must be oriented with flats on actuator, otherwise valve will be
opened when it should be closed or visa--versa.
3. Rotate stem (12) on valve body (10) so that is aligned with flats (13) on actuator (6).
4. Mate new valve body (10) with flanges (11) then install, but do not tighten, two screws (8) and nuts (9).
5. Install actuator (6) and adapter (7).
6. Install, but do not tighten, two screws (4) nuts (5).
7. Evenly tighten screws (4 and 8).
8. Connect tubes (1) to elbows (2) as tagged.
9. Perform a HEAT WATER operation (TM 10--3510--221--10). While water is heating visually check for
steam/water leaks.
END OF WORK PACKAGE