TM 10--3510--221--24
0160 00--2
STILL CONDENSER FAN BLADE REPLACEMENT --
Continued
0160 00
6
4
5
12
11
13
9
10
1
1
2
1
8
3
7
INSTALLATION
1. Install Install machine key (12) onto motor shaft (8).
2. Slide new fan blade (11) over machine key (12) onto motor shaft (8).
3. Position fan blade (11) to previously recorded dimension, then tighten two setscrews (10).
4. Slowly spin fan blade (11) and check gap between blade tips (13) and fan shroud (7). If gap is less than 1/8
inch at any location adjust fan motor position (WP 0267 00).
5. Position blade guard (6) onto fan shroud (7), then secure with four screws (4) and lock washers (5).
6. Position cooling air shroud (2) onto still condenser frame (3), then secure with five screws (1).
7. Perform a HEAT TANKS operation (TM 10--3510--221--10). Verify smooth rotation of condenser fan.