TM 10--3510--221--24
0164 00--1
SUBCOOLER INLET VALVE REPLACEMENT
0164 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Sealant, Pipe Thread (Item 6, WP 0271 00)
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
LADS power shut off at main control
enclosure (WP 0112 00).
REMOVAL
WARNING
Distillate piping can reach temperatures near 200o F when the water recycle system is
operating. Allow piping to cool prior to performing maintenance. Always wear gloves and
eye protection. Failure to follow this precaution could result in severe burn injuries.
1. Disengage two latches (1), then open access door (2).
2. Open petcock (3). Allow water to drain then close petock.
3. Loosen screw (4) then disconnect electrical cable (5) from solenoid valve (6).
4. Loosen clamp (7) then pull hose (8) off of piping (9).
5. Loosen clamp (10) then pull hose (11) off of piping (12).
6. Disconnect union (13).
7. Loosen clamp (14) securing piping (12) to distillate frame (15) then remove solenoid valve (6) with attached
piping (9) and (12).
8. Unthread hex bushing (16) from inlet of solenoid valve (6).
9. Unthread hex bushing (17) from outlet of solenoid valve (6).
10. Clean pipe thread sealant from threads of hex bushings (16 and 17) and mating surfaces of union (13).