TM 10--3510--221--24
0164 00--2
SUBCOOLER INLET VALVE REPLACEMENT --
Continued
0164 00
3
13
14
12
10
11
4
5
15
18
6
9
8
7
2
1
16
17
INSTALLATION
1. Apply pipe thread sealant to threads of hex bushings (16 and 17) and mating surfaces of union (13).
2. Note direction arrow (18) on new solenoid valve (6) then thread hex bushing (17) into valve outlet.
3. Thread hex bushing (16) into inlet of solenoid valve (6) and orient as shown.
4. Connect, but do not tighten union (13).
5. Connect hose (11) at piping (12) then tighten clamp (10).
6. Connect hose (8) at piping (9) then tighten clamp (7).
7. Install, but do not tighten clamp (14).
8. Tighten union (13) then clamp (14).
9. Connect electrical cable (5) to solenoid valve (6) then tighten screw (4).
10. Perform a HEAT WATER operation with a water temperature setpoint of 110 degrees F (TM 10--3510--221--10).
Verify no water leaks exist.
11. Close access door (2) and secure by engaging two latches (1).
END OF WORK PACKAGE