TM 10--3510--221--24
0210 00--1
ANALOG PCB ASSEMBLY REPLACEMENT
0210 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tags (Item 9, WP 0271 00)
Washer, Lock (Item 17, WP 0275 00)
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
LADS water tanks must be drained and air
system vented (TM 10--3510--221--10).
LADS power must be shut off and door opened at
main control enclosure (WP 0112 00).
REMOVAL
1. ESD. Loosen screw (1) then disconnect ground wire (2).
2. ESD. Loosen screw (3) then disconnect shield wire (4).
3. ESD. Loosen screw terminals (5), then tag and disconnect wiring from J1 connector (6).
4. ESD. Disconnect ribbon cable (7) from J2 connector (8).
5. ESD. Disconnect pressure sensor PT200 (9) from J5 connector (10).
6. ESD. Disconnect level sensor LT102 (11) from J6 connector (12).
7. ESD. Disconnect level sensor LT201 (13) from J7 connector (14).
8. ESD. Disconnect level sensor LT200 (15) from J8 connector (16).
9. ESD. Disconnect level sensor LT101B (17) from J9 connector (18).
10. ESD. Disconnect level sensor LT100B (19) from J10 connector (20).
11. ESD. Disconnect level sensor LT101A (21) from J11 connector (22).
12. ESD. Disconnect level sensor LT100A (23) from J12 connector (24).
13. ESD. Disconnect wire harness (25) from J13 connector (26).
14. ESD. Disconnect wire harness (27) from J14 connector (28).
15. ESD. Disconnect wire harness (29) from J15 connector (30).
16. ESD. Remove screws (1 and 3) and lock washers (31 and 32).
17. ESD. Remove four screws (33) and lock washers (34) then remove analog PCB (35) from standoffs (36).