TM 10--3510--221--24
0208 00--2
ORIFICE MANIFOLD FILTER REPLACEMENT --
Continued
0208 00
3
4
5
6
9
7
8
INSTALLATION
1. Apply anti--seizing tape to threads of connector (6) and nipple (8).
2. Thread connector (6) onto new filter (7) with direction arrow (9) pointing away from connector.
3. Thread filter (7) onto nipple (8).
4. Connect tube (5) to connector (6).
5. Open manual valve (3).
6. Use maintenance menu to test air system (WP 0010 00). After air system is pressurized audibly check for air
leaks.
7. Close access door (2) and secure by engaging two latches (1).
END OF WORK PACKAGE