TM 10--3510--221--24
0210 00--3/4 blank
ANALOG PCB ASSEMBLY REPLACEMENT -- Continued
0210 00
INSTALLATION
1. ESD. Position new analog PCB (35) on standoffs (36). Install, but do not tighten, four screws (33) and lock
washers (34).
2. ESD. Install, but do not tighten, screws (1 and 3) and lock washers (31 and 32).
3. ESD. Connect shield wire (4) then tighten screw (3).
4. ESD. Connect ground wire (2) then tighten screw (1).
5. ESD. Tighten four screws (33).
6. ESD. Connect wire harness (29) to J15 connector (30).
7. ESD. Connect wire harness (27) to J14 connector (28).
8. ESD. Connect wire harness (25) to J13 connector (26).
9. ESD. Connect level sensor LT100A (23) to J12 connector (24).
10. ESD. Connect level sensor LT101A (21) to J11 connector (22).
11. ESD. Connect level sensor LT100B (19) to J10 connector (20).
12. ESD. Connect level sensor LT101B (17) to J9 connector (18).
13. ESD. Connect level sensor LT200 (15) to J8 connector (16).
14. ESD. Connect level sensor LT201 (13) to J7 connector (14).
15. ESD. Connect level sensor LT102 (11) to J6 connector (12).
16. ESD. Connect pressure sensor PT200 (9) to J5 connector (10).
17. ESD. Connect ribbon cable (7) to J2 connector (8).
18. ESD. Connect wiring to J1 connector (6) as tagged then tighten screw terminals (5).
19. ESD. Connect wiring to J1 connector (6) as tagged then tighten screw terminals (5).
20. Turn handle (37) CW, then close door (38).
21. Secure door (38) to main control enclosure (39) by tightening eleven latches (40).
22. Using maintenance menu calibrate levels sensors (LT100A through LT201), pressure sensors (PT200 through
PT501), and temperature sensors (TE100 through TE300) (WP 0010 00).
23. Perform DAILY START--UP and a test LAUNDRY CYCLE (TM 10--3510--221--10). Verify normal operation.
END OF WORK PACKAGE