TM 10--3510--221--24
0264 00--7/8 blank
HEATER ASSEMBLY REPLACEMENT --
Continued
0264 00
21. Mate connectors (27) to three pressure sensors (28) then tighten screws (26).
22. Install tiedown straps (31) as necessary to secure sensor cable (32) to conduit (33).
23. Install tiedown straps (34) as necessary to secure door sensor cable (35) and air tubing (36) to heater (24).
24. At connections for inlet hose (17) and outlet hose (18) perform the following, one connection at a time:
a. Apply a light coat of thermal fluid to a new gasket (23), then install gasket at hose connection.
b. Mate hose connection and install halves of clamp (22).
c. Install, but do not tighten two screws (19), lock washers (20), and nuts (21).
d. Evenly tighten two screws (19).
25. Connect fuel hoses (1 and 2) to quick--connect fittings (3 and 4).
26. Clean--up any residual thermal fluid on heater (24) and surrounding equipment.
27. Replenish thermal fluid supply and leak check connections (WP 0169 00).
END OF WORK PACKAGE