TM 10--3510--221--24
0010 00--8
LAUNDRY ADVANCED SYSTEM
MAINTENANCE MENU OPERATION -- Continued
0010 00
C. CONTROLLING OUTPUTS --Continued
19. Monitor display, it should read:
HEATING SYSTEM ON
TF TEMPERATURE = 300 F
HEATER DELTA P = 20 PSID
STOP HEATING SYS
or
AIR SYSTEM ON
AIR TANK PRESS = 105 PSIG
STOP AIR SYSTEM
20. After operational check is completed press MENU SELECTION switch to turn off air or heating system.
Return to step 18.
TABLE 3. Motor Data.
MOTOR
FUNCTION
CONTROL DEVICES
PROTECTION DEVICES
M100A
Drum A Rotation
K100A
K100A/CB3
M100B
Drum B Rotation
K100B
K100B/CB4
M101A
Water Pump A
MC101A
OL101A/CB5
M101B
Water Pump B
MC101B
OL101B/CB5
M102A
Detergent Pump A
PCB3/SSR22
CB7
M102B
Detergent Pump B
PCB3/SSR14
CB7
M104A
Dryer Blower A
K104/MC104A
OL/104A/K104/CB2
M104B
Dryer Blower B
K104/ MC104B
OL104B/K104/ CB2
M105
Water Supply Pump
MC105
OL105/CB5
M106A
Drum Motor A Fan
SW1
F4--6/CB2
M106B
Drum Motor B Fan
SW1
F4--6/CB2
M107
Inverter Enclosure Fan
SW1
F5--6/CB2
M200
Still Condenser Fan
K200
OL200/K200/CB1
M201
Distillate Pump
MC201
OL201/CB6
M202
Anti--Foam Pump
PCB3/SSR13
CB7
M300
Thermal Fluid Pump
K200
OL300/K200/CB1
M301
Burner Blower
K200/MC301
OL301/K200/CB1
M500
Air Compressor
K500