TM 10-3510-222-10
2-12. OPERATION IN COLD- continued.
a.
Operating When Laundry Unit is Set-up - continued.
(g)
Disconnect hose from drain valve.
(h)
Close draincock 50 ips on top of water heater.
(i)
Refer to TM 10-4520-259-13&P for any questions about water heater.
(3)
Remove water from valves per substeps below:
(a)
On washer air tank, make sure gage has at least 90 psi. If less than 90 psi, start generator. (Refer to
TM 5-6115-585-12.)
(b)
Remove cap from washer recycle drain.
(c)
On washer control panel back side, turn yellow arrow to the right 90°
and back three times to drain
water from the following valves:
1.
RECYCLE DRAIN
2.
HOT INTAKE
3.
COLD INTAKE
(d)
Install cap on washer recycle drain
(e)
If generator was running, shut down and refer to TM 5-6115-585-12.
(4)
Water Pump. Do substeps below:
(a)
Connect nonmetallic hose quick coupling half on outlet side of water pump and inlet quick coupling
half of water heater.
(b)
Connect nonmetallic hose to quick coupling half on inlet side of water pump.
(5)
Washer. Do substeps below:
(a)
Open draincock under washer air tank and drain any water.
(b)
Close draincock on washer air tank.
b.
Generator. Refer to TM 5-6115-585-12 for cold weather operation.
c.
Water Heater. Refer to TM 10-4520-259-13&P for cold weather operation
d.
Trailer. Refer to TM 9-2330-376-14&P for cold weather operation.
2-88