Table 3-1. Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
NO POWER TO COMPONENT CIRCUIT BREAKERS - continued.
d.
Close door on power distribution panel.
e.
Apply electrical power. Refer to generator TM 5-6115-585-12.
Step 2.
Check for electrical power on generator.
a.
Place AC CIRCUIT BR3EAKER to ON.
b.
If no electrical power, notify unit maintenance.
2.
WATER PUMP FAILS TO START.
Check for electrical power.
a.
Set ON/OFF switch to OFF
b.
Make sure distribution power cable is plugged in.
c.
Push terminal overload protector on motor.
d.
Open power distribution panel and see if water heater number 5 circuit breaker has tripped, if
tripped reset circuit breaker. Close power distribution panel.
e.
Set ON/OFF switch on water pump to ON.
f.
If water pump fails to start, set ON/OFF switch to OFF on water pump and notify unit maintenance.
3.
WATER PUMP FAILS TO DELIVER WATER.
Step 1
Check pump to verify adequately primed.
a.
Set ON/OFF switch to OFF.
b.
If pump is not primed, refer to paragraph 2-8b water pump and prime pump.
c.
Set ON/OFF switch to ON.
3-3