TM 10-3510-222-24
2-33. AIR MANIFOLD.
This task covers:
a. Removal
b. Disassembly
c. Repair
d. Assembly
e. Installation
INITIAL SETUP
Tools
General Mechanics Tool Kit (App B, Item 1)
Materials/Parts
Antiseize Compound (App D, Item 24)
Equipment Condition
Laundry Unit shut down (TM 10-3510-222-10)
General Safety Instructions
WARNING
High voltage is present on this
equipment.
Do
not
perform
maintenance with power on. Death
or serious injury may result.
a. REMOVAL
(1) On washer air tank, open drain cock until pressure gage reads 0 psi.
(2) Close drain cock (Para 2-31, Air Tank).
(3) Remove five hose clamps (1) from air hoses (2, 3, 4, 5 and 6).
(4) Remove air hoses (2, 3, 4, 5 and 6) from air manifold (24).
(5) Remove hose (7) from adapter (12).
(6) Remove hose (8) from adapter (13).
(7) Remove four nuts (9), lockwashers (10), two plates (11) and air manifold (24).
b. DISASSEMBLY
(1) Remove adapter (12) from tee (14).
(2) Remove adapter (13) from tee (14).
(3) Remove tee (14) from nipple (15).
(4) Remove adapter (16) from pipe cross (18).
(5) Remove adapter (17) from pipe cross (18).
(6) Remove pipe cross (18) from nipple (19).
(7) Remove nipple (19) from pipe cross (23).
(8) Remove adapter (20) from pipe cross (23).
(9) Remove adapter (21) from pipe cross (23).
(10) Remove adapter (22) from pipe cross (23).
2-85