TM 10-3510-222-24
2-32. PRESSURE GAGE.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools
General Mechanics Tool Kit (App B, Item 1)
Materials/Parts
Antiseize Compound (App D, Item 24)
Equipment Condition
Laundry Unit shut down (TM 10-3510-222-10)
General Safety Instructions
WARNING
High
voltage
is
present
on
this
equipment.
Do
not
perform
maintenance with power on. Death or
serious injury may result.
a. REMOVAL
(1) Remove sensor (1) from bushing (5).
(2) Remove two nuts (2) and brackets (3) from pressure gage (4).
(3) Remove pressure gage (4) from drum (6).
b. INSTALLATION
(1) Position pressure gage (4) on drum (6) and install two brackets (3) and nuts (2).
(2) Apply antiseize compound to male threads of sensor (1).
(3) Install sensor (1) on bushing (5).
2-83