2-46. PIPING - continued.
(5)
Quick Coupling Half (5).
(a)
Remove piping.
(b)
Remove clamp (33) from hose (34).
(c)
Remove quick coupling half (5).
(d)
Install new quick coupling half (5).
(e)
Using Band-it Jr., install clamp (33) on hose (34).
(f)
Install piping.
(6)
Quick Coupling Half (5 and 6).
Repair consists of replacing gaskets (35 and 36).
(7)
Rubber Hose (34).
(a)
Remove piping.
(b)
Remove three clamps (32 and 33).
(c)
Remove quick coupling half (5) from rubber hose (34).
(d)
Remove rubber hose (34) from adapter (31).
(e)
Cut new rubber hose (34) to eight inches.
(f)
Install rubber hose (34) on adapter (31).
(g)
Install quick coupling half(5) on hose (34).
(h)
Using Band-it Jr., install three clamps (32 and 33).
(i)
Install piping.
c.
INSTALLATION
(1)
Position piping on water heater.
(2)
If water heater was replaced, install nut (4) and tube (8).
NOTE
Piping should be placed between the threaded rods (refer to Para 2-45).
(3)
Lock quick coupling half (5 and 6).
(4)
Install coupling nut (4) on adapter (25).
(5)
Install hose (3) on elbow (38).
(6)
Install hose (2) on elbow (37).
(7)
Install hose (1) on quick coupling half (13).
(8)
Install upper clamps (Para 2-45).
(9)
Install water heater exhaust pipe (TM 10-3510-222-10).