TM 10-3510-223-13&P
0009 00
0009 00-3
THIS SECTION COVERS:
Before Operation PMCS Checks and Services
INITIAL SETUP:
CSSL set up. Water and power connected
Materials/Parts
Maintenance Level
Rags (WP 0071, Table 1, Item 1)
Operator/Unit
Fluorescent Light bulbs
Tools and Special Tools
(WP 0071, Table 1, Item 2)
None
Table 0009 00-1. Preventive Maintenance Checks and Services for CSSL
ITEM
NO.
INTERVAL
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT NOT READY/
AVAILABLE IF:
1
Before
Washer/Dryers Open washers (1) to determine if they
contain any water that has not drained
properly, clothes, or other items. Drain
water by activating washer. (If problem
persists unclog drain line as described
in work package 0012 00) Check the
condition and proper attachment of the
freshwater supply (2) and wastewater
drain (3) hoses. Check for leaks.
Check and, if needed, clean out dryer
lint traps (4). Check secure attachment
and general condition of dryer exhaust
ducts (5)
Washers contain water of previous
wash cycle, clothes or other items.
Dryers that contain clothes or other
items. Dryer lint traps are clogged.
Dryer exhaust hoses loose, clogged
or damaged. Water supply or drain
hoses loose, damaged or missing.
Washers leak.
2
Before
Water Service
Panels
Check the freshwater (6) and
wastewater (7) panels for physical
damage, leaks and corrosion.
Panels or QD fittings are damaged.
Hoses are improperly connected
and leaking. Excessive corrosion.
3
Before
Interior Lights Activate interior lights (8) and check
their operation. Replace any burned
out light bulbs (9) as required. Refer
inoperative light switch to unit
maintenance and inoperative light
fixtures to direct support maintenance.
Inoperative light fixtures, light
switch, and excessive number of
light bulbs burned out.
4
Before
Vent Fan
Activate exhaust fan (10) and
determine its proper operation. Refer
an inoperative ventilation fan to direct
support maintenance.
Inoperative vent fan. Noisy
operation. Power cord damaged.
5
Before
Space Heater
Activate space heater (11). Determine
its operation. Check for functioning of
the heater control (12). Check for any
physical damage to the unit.
6
Before
Power Entry
Box
Check for physical damage to panel
(13) connectors, and cables (14).
Ensure cables are properly connected.
(Refer to work package 0005 00)
Damaged panel or connectors.
Improper or loose electrical
connections