TM 10-3510-223-13&P
0009 00
0009 00-4
Table 0009 00-1. Preventive Maintenance Checks and Services for CSSL - Continued
ITEM
NO.
INTERVAL
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT NOT READY/
AVAILABLE IF:
7
Before
TEMPER
Modified End
Section
Check bootwall (15) for rips and tears,
missing hardware, or improper
installation. Check cinch-strap (16)
around boot for tightness.
Ripped and torn fabric. End wall not
properly installed.
8
Before
Circuit
Breakers
WARNING
ELECTROCUTION
Do not touch damaged circuit
breakers. Notify direct support
maintenance.
Open circuit breaker boxes (17) and
examine circuit breakers. Note any
damage to breakers and the box. If no
damage is noted, activate the breakers
to determine their proper functioning.
Damaged or non-functioning circuit
breakers.
9
Before
Interior GFCI
Receptacle
With the main circuit breaker (#33)
of power distribution panel #1 set to
ON, set circuit breaker #10 to ON
and test the GFCI receptacle in the
roadside raceway (18) by pushing
the TEST button. Observe light
indicator. If light indicator does not
activate, push the RESET button.
Repeat test. If receptacle does not
work, replace it as described in
work package 0016.