TM 10-3510-223-13&P
0012 00
0012 00-5/6 Blank
PROCEDURE 4 COVERS:
Wastewater Alarm Activated
INITIAL SETUP:
CSSL set up but not in operation
Maintenance Level
Materials/Parts
Unit
None
SWITCH CIRCUIT BREAKER #2 ON
POWER DISTRIBUTION PANEL #1TO ON
PLUG SERVICEABLE POWER CORDS OF
THE PUMP AND FLOAT SWITCHES INTO
THE RECEPTACLES AS MARKED. NOTIFY
DS MAINTENANCE IF ANY POWER CORD
IS BROKEN, CUT OR OTHERWISE
UNSERVICEABLE.
SET ALL CIRCUIT BREAKERS TO OFF,
AND NOTIFY DS MAINTENANCE
TURN PUMP OFF. CHECK WASTEWATER
HOSE AND TANK LINE FOR CLOGGING.
CLEAN OUT AS NEEDED
AFTER PUMP HAS SHUT OFF, TEST THE
ALARM BY PUSHING THE 'ALARM TEST'
BUTTON
NO
YES
NO
NO
NO
YES
YES
YES
WITH CIRCUIT BREAKER #10 ON POWER
DISTRIBUTION PANEL #1 SET TO OFF,
CHECK PUMP AND FLOAT SWITCH POWER
CORDS. ARE THEY SERVICEABLE AND
PROPERLY PLUGGED IN?
WITH CIRCUIT BREAKER #10 ON POWER
DISTRIBUTION PANEL #1 SET TO ON,
PUSH THE 'PUMP ON' BUTTON ON THE
WASTEWATER ALARM. DOES PUMP RUN?
IS WASTEWATER BEING EVACUATED?
IS CIRCUIT BREAKER # 2 ON POWER
DISTRIBUTION PANEL #1ON?
END OF WORK PACKAGE