THIS SECTION COVERS:
Inspect and Repair
INITIAL SETUP
Circuit Breaker #1 in circuit breaker box #1 set to OFF
Maintenance Level
Unit
Materials/Parts
Tools and Special Tools
Light Fluorescent, General Purpose
Tool Kit General Mechanic (WP 0045, Table 2, Item 1)
(WP 0072 00, Table 1, Item 2)
WARNING
This equipment operates at High Voltages. Use extreme caution. Turn
Circuit Breaker #1 in Circuit Breaker Box #1 OFF before proceeding with
this procedure. Touching a live wire can cause serious injury or death.
INSPECT
Using a flashlight (in footlocker), inspect the fluorescent light fixtures for damage and security of
mounting. Check for presence and security of cover (1).
REPAIR
To replace a burned out light bulb (2) un-clasp and remove the cover (1). Remove the retainer clips (3)
holding the light bulb in the sockets (4) and retain. Turn the burned out light bulb slightly and remove it
from its sockets.
Remove the insulators (4) from both ends of the light bulb and retain.
While the light bulb is removed, check the security of fixture mounting hardware. Tighten if necessary.
Place the insulators (4) removed from the old lightbulb onto the new bulb to be installed so that the slotted
end faces down and outward from the bulb.
Install the new lighbulb (2) into the fixture and secure with retainer clips (3).
Replace cover (1).