TM 10-3510-223-13&P
0013 00
CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) MODEL A
UNIT MAINTENANCE
0013 00-1/(2 Blank)
POWER ENTRY CONNECTORS
THIS SECTION COVERS:
Inspect
INITIAL SETUP
CSSL shut down. All power cables disconnected
Maintenance Level
Unit
Tools and Special Tools
Materials/Parts
Tool Kit General Mechanic (WP 0045, Table 2, Item 1)
WARNING
This equipment operates at High Voltages. Use extreme caution.
Turn OFF power supply and disconnect all power cables from the power
entry box. Touching a live wire can cause serious injury or death.
INSPECT
Inspect the power input plugs J1 (1) and J2 (2) for damage. Check for bent connector pins (3), corrosion,
and stripped or otherwise damaged threads (4). Check for presence and serviceability of protective cover
(5). Check pan head screws (6) securing the plugs to the panel and tighten if necessary. Check GFCI
Receptacle J3 (7) and external receptacle J4 (8) for corrosion, clogged pinholes, missing covers and
loose or missing hardware. Have any unserviceable plug or receptacle replaced through direct support
maintenance.
END OF WORK PACKAGE
2
1
3
4
5
6
7
8
Check ground terminal (9) for serviceability.
9