TM 10-3510-224-13&P 0011 00
CONTAINERIZED SELF SERVICE LAUNDRY (CSSL)
NSN 3510-01-485-0457
SERVICE UPON RECEIPT
0011 00-1
General.
To ensure proper functioning of the equipment, perform all tasks prescribed in this work package.
The CSSL is shipped via truck and contains the following components:
One TEMPER, 8 ft Window Section
One Grounding Rod
One TEMPER ISO Modified End Section
One Garden Hose
One TEMPER End Section
One 3,000 Gallon Wastewater Tank
One Freshwater Hose
One 3,000 Gallon Freshwater Tank
One Wastewater Hose
Two Pigtails
Two 100 AMP, 50 ft Power Cables
One TEMPER Frame Section
One Footlocker
WARNING
The Containerized Self Service Laundry is shipped with an anti-freeze
solution pumped into the freshwater lines. The anti-freeze solution is
non-toxic, but is unsuitable for drinking or washing. DO NOT OPERATE
THE CSSL until the freshwater lines are flushed.
Once the CSSL is functional, flush the freshwater lines by operating each washer for two complete cycles.
WARNING
The laundry components are heavy. To avoid injuries, four persons are
required to unload, move and position the components.
Required tasks upon Receipt of the CSSL.
Unpacking. Open the general cargo container personnel door marked OPEN FIRST and remove the
components stored inside.
Packing list verification. Check the components removed against the packing list to see if the shipment
is complete. Report all discrepancies in accordance with DA Pam 738-75.