Table 1. Electrical Troubleshooting Procedures for Containerized Batch Laundry - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. No electrical power to
washers and PLC.
WARNING
WARNING
The equipment being tested or
The equipment being tested or
corrected operates at high
corrected operates at high voltages
voltages and current that can
and current that can cause serious
cause serious injury or death.
injury or death.
Check for power at cable
Step 1. Check all electrical cables
connections. If no power is
(Figure 3, Item 1) for proper
present, check power source.
connection. Ensure power source is
operating correctly.
Replace damaged power input
Step 2. Inspect and test power input
receptacle.
panel (Figure 3, Item 2) IAW WP 0018
Inspect and test breaker IAW
Step 3. Check main circuit breaker
(Figure 3, Item 3).
Replace if necessary.
If further corrective action is
required, notify direct support
maintenance.
2
3
1
Figure 3. No Electrical Power to Washers and PLC.