TM 10-3510-226-23
0023 00
REPLACE
Replace Receptacles
WARNING
This equipment operates at high voltages. Use extreme caution, observe all warnings,
and follow all safety procedures. Failure to observe safety precautions may result in
injury or death to personnel.
1. Switch appropriate circuit breaker to OFF, and disconnect plug from the receptacle (Figure 2, Item
1). Refer to Table 2 as necessary.
Receptacle
Circuit Breaker(s)
Washer No. 1
No. 2 and No. 4
P-2 WTS Transfer Pump
No. 6
Washer No. 2
No. 10 and No. 12
Waste Pump P-5
No. 13
No. 24
Automatic Soap Dispenser
No. 29
2. Remove screws retaining receptacle cover (Figure 2, Item 3) and remove cover.
3. Remove screws retaining receptacle (Figure 2, Item 1) to box (Figure 2, Item 4) and remove
receptacle.
4. Tag and disconnect wiring from receptacle (Figure 2, Item 1).
5. Connect wiring to replacement receptacle (Figure 2, Item 1) as tagged.
6. Install receptacle (Figure 2, Item 1) into box (Figure 2, Item 4) and retain with screws.
7. Install cover (Figure 2, Item 3), and retain with screws.
8. Switch main breaker ON and monitor for normal operation.
0023 00-4