TM 10-4510-207-14
This task covers: a. Removal b. Installation
INITIAL SETUP
Tools:
Equipment Conditions:
Shower facility not in use.
Item 1)
Shower facility shut down and power disconnected,
Pipe Wrench (Appendix B, Section III, Item 2)
Fitted Wrench (Appendix B, Section III, Item 2)
General Safety Instructions:
Materials/Parts:
WARNING
High voltage is used on the portable shower
module. Care must be taken to avoid personal
injury or death from energizing circuits.
a. Removal.
(1) Release coupling (1) and disconnect mating hose end coupling.
(2) Release mating hose end coupling connected to coupling (2) and disconnect.
(3) Loosen nut (3) and remove cover (4). Tag and disconnect wire leads form pressure switch (5).
(4) Remove four screws (6), cover (7), and gasket (8). Tag and disconnect wire leads from supply pump (9).
(5) Remove conduit, with wire leads inside, from two conduit connectors (10) then remove conduit connectors.
(6) Release coupling (11) and remove plug (12).
(7) Remove clod line hose assembly from cross fitting (13). See paragraph 4.12.
(8) Remove coupling (2), bushing (14), strainer (15), and nipple (16).
(9) Remove coupling (11), coupling (17), nipple (18), and bushing (19).
(10) Remove coupling (1).
(11) Remove pressure switch (5) and nipple (20).
(12) Remove cross fitting (13) and nipple (21).
(13) Remove four self-locking nuts (22), flat washers (23), bolts (24), flat washers (25), and supply pump (9).
Discard self-locking nuts.
4-29