Table 1. Preventive Maintenance Checks and Services (PMCS) for MMKs - Continued
OPERATOR MAINTENANCE MMK AVALANCHE TRANSCEIVER TEST

OPERATOR MANUAL FOR MILITARY MOUNTAINEERING KITS
Page Navigation
  60    61    62    63    64  65  66    67    68    69    70  
img
. . . .
TM 10-8465-237-10
0014
OPERATOR MAINTENANCE
MILITARY MOUNTAINEERING KITS TRANCEIVER BATTERIES
REPLACE
INITIAL SETUP:
Personnel Required
Materials/Parts
Mountaineer (1)
Batteries, Alkaline (WP 0029, Item 1)
Equipment Condition
Tools
Battery level below 20 percent
Tool Kit, Small Arms (WP 0029,
Item 11)
REPLACE
1.
Locate the battery door of the avalanche transceiver, and loosen screw (Figure 1).
SCREW
Figure 1. Back of Transceiver.
2.
Remove all three batteries, and discard IAW unit SOP.
3.
Replace with three new AAA alkaline batteries, ensuring the positive and negative ends of the
batteries are properly aligned.
4.
Replace battery door, and tighten screw.
5.
Turn unit on to verify battery charge is over 20 percent. Turn off.