200-AO
DANGER
THIS EQUIPMENT CAN BE HAZARDOUS TO THE OPERATOR'S SAFETY AND ONLY AUTHORIZED PERSONNEL WHO HAVE READ AND UNDER-
STAND THE INSTALLATION AND OPERATING MANUAL SHOULD BE PERMITTED TO OPERATE THIS UNIT. D0 NOT ALLOW THIS EQUIP-
MENT TO OPERATE UNATTENDED.
1.0
GENERAL
1.1
These instructions are published
for Model 200-AO Diesel Fuel
Steam Cleaner. Paragraphs 3.0 through 10.0 provide necessary information on the operation, maintenance,
and trouble shooting of the equipment, components and attachments,
2.0
DESCRIPTION AND DATA
200-AO Diesel Fuel Fired Steam Cleaner has a capacity Of 200
2.1
Description:
The
gallons per hour and 200 gallons per hour cold water rinse. The cleaner has a fuel tank, soap solution
tank, burner assy, heating coils, electric motor, together with all necessary controls, pumps and connec-
tions for using where there is an available electrical and pressured water source of 25 to 125 P.S.I. or
other outside source of water. Unit is designed to operate at 80 to 100 PSI solution pressure.
Tabulated Data:
Distributor: Not Applicable
A.
Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200-AO
B.
Fuel :
Type: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fuel oil, #l or #2 diesel fuel,
WARNING
D0 NOT use gasoline, solvent or improper rated fuels in this equipment and only fill fuel tank
when unit is in off condition, main power disconnected and all components are cool. FAILURE TO
D0 SO COULD RESULT IN SEVERE OR POSSIBLE FATAL INJURY TO PERSONNEL,
Tank Capacity . . . . . . . . . . . . . . . . . . . . . . Approximately 20 gallons
Running Time . . . . . . . . . . . . . . . . . . . . . . Approximately 5 hours
c.
Soap Solution . . . . . . . . . . . . . . . . . . . . . . Liquid or powdered conforming to P-C 437
Tank Capacity . . . . . . . . . . . . . . . . . . . . . . Approximately 20 gallons
D.
Dimensions and Weight:
Crated
Uncrated
Vo1ume
Overall length . . . . . . . . . . .
64.0 inches . . . . . . 59.5 inches
Crated . . . . 86.8 Cubic Feet
Overall width . . . . . . . . . . . .
43.0 inches . . . . . . 38.0 inches
Uncrated.. 64.8 Cubic Feet
Overall height . . . . . . . . . . .
54.5 inches . . . . . . 49,5 inches
Weight (dry) . . . . . . . . . . . .
815.0 pounds
(dry) 730,0 pounds
(wet) 1100.0 pounds
E.
Electrical
Equirements:
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . .
230 volts, single phase, 60Hz is standard unless optional
voltage has been specified. Check serial numbered data plate
for proper voltage requirement.
Amps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15 amp source
F.
Water Requirements:
Size of pressure line . . . . . . . . . . . . . 3/4" - 220 GPH continuous capacity
Pressure . . . . . . . . . . . . . . . . . . . . . . . . . .
Size of auxiliary water supply hose - 1" 1.D. x 30' with strainer and foot valve (furnished).
Requirements: . . . . . . . . . . . .
G.
Venting
Units located within or near a flammable structure must be
vented away from structure. Should venting be required due
to location Installation, Adapt a 30" x 10" I.D. Stack to
unit and place a 10" 1.D. down draft diverter between this
30" x 10" 1.D. stack and balance of stack.