(3) Install the union tees (26 and 29), nipples
(25 and 28) and bushings (24 and 27) onto the
water container (35).
Do not use compressed air for cleaning
(4) Install the sight glass (22), packings (19
purposes except where reduced to less than
and 21) and mounting rings (18 and 20) in the
30 psi and then only with effective chip
sight glass guard (23).
guarding and personal protective equip-
(5) Position the water level sight assembly
ment.
(17) with the sight gage bushings (24 and 27)
Clean all parts of the water level control, with
contacting the glass guard (23), then insert and
dry compressed air and a clean cloth and dry
tighten the bushings to secure.
thoroughly.
(6) Install the pipe plugs (15 and 16, fig.
d. Inspection.
4-87) .
(1) Inspect the water container for cracks,
(7) Install the pipe nipple (14), elbow (13),
dents, nicks and other damage.
nipple (12) and cross (11) on water container (35).
(2) Inspect the air hoses and packing and
(8) Install the temperature gage (10) and hose
other parts for cracks, pits, holes and other leak
adapter (9) on cross (11).
causing conditions.
(9) Install the nipple (8), coupling (7), bushing
(3) Inspect all hardware and piping for thread
(6), nipple (5) and gate valve (4).
damage.
(10) Install the nipple (3), elbow (2) and hoes
e. Repair.
(1) The water container, if damaged, should
adapter (1) on the gate valve (4).
be replaced.
(2) Replace all damaged hardware and piping.
the water control level.
f. Assembly.
below listed instructions to adjust the water level
water container (35).
control.
(2) Position the water height graduator (33)
on the water container and secure with screws (32),