TM 10-3510-209-24
2-47. DRYER UV SCANNER AND FLAME SAFEGUARD ASSEMBLY (CONT)
REMOVAL (Cont)
WARNING
Heated parts may cause injury to
personnel if safety precautions are
not followed. Allow burner area to
cool before any maintenance actions
are
performed
on
the
burner
assembly.
7.
Remove UV scanner (10) from burner cover
(11).
8.
Loosen two clamps (12) and remove UV
scanner (10) and attached wires from conduit
connector (13).
9.
Remove four mounting screws (14) and base (9)
from the electrical panel.
SERVICE
1.
Clean lens of UV scanner with a soft cloth (Item
3, App C) moistened with water. Dry lens with a
dry, soft cloth.
2.
Use a small brush to clean carbon deposits from
the inside of scanner tube.
REPAIR
Repair of the UV scanner and flame safeguard assembly
consists
of
replacing
the
defective
components.
Remove and replace only those items necessary to
make repair. If replacement of individual parts is not
practical, then replace the next higher assembly.
INSTALLATION
NOTE
UV scanner wires are 72 inches (1.83 m) long and are routed through the entire
length of the conduit to the flame safeguard control.
1.
Install base (9) and secure with four mounting screws (14).
2-170