TM 10-3510-209-24
2-48. DRYER AIR SHUTTER ASSEMBLY (CONT)
REPAIR
NOTE
A cracked housing or flange can be
repaired
by
proper
welding
procedures.
1.
Replace shutter (2) and/or blower impeller (13) if
damaged.
2.
Use a wire brush and remove accumulated
matter from filter screen (6).
3.
Replace missing or damaged hardware.
INSTALLATION
1.
Install flange (17) on motor (18) and secure with four lockwashers (16) and capscrews (15).
2.
Install key (14) on shaft of motor (18).
3.
Install blower impeller (13) on shaft of motor (18) and tighten setscrews (12).
4.
Install coupling (11) on shaft of motor (18) and tighten setscrew (10).
5.
Position blower housing (9) on flange (17) and secure with eight lockwashers (8) and fan capscrews (7).
6.
Install filter screen (6) and air intake housing (5) onto blower housing (9) and secure with four lockwashers (4) and
capscrews (3).
7.
Install shutter (2) on air intake housing (5) and secure with thumbscrew (1).
NOTE
FOLLOW-ON MAINTENANCE:
Install tarp assembly (TM 10-2510-209-10).
2-173