TM 10-3510-209-24
3-17. EXTRACTOR DRIVE UNIT (CONT)
INSTALLATION (Cont)
NOTE
You should be able to pull/push the top of the drive shaft approximately 1/2 inch
(12.7 mm) off center. If movement is less than 1/2 inch (12.7 mm), add a flat washer
under the trunnion caps. If movement is more than 1/2 inch (12.7 mm), remove flat
washer from under the trunnion caps.
2.
Lubricate brake mechanism and gyro ball. Refer to LO 10-3510-209-12.
3.
Connect three brake solenoid wires (1) to brake solenoid (2). Remove tags.
4.
Refer to paragraph 3-16 REPAIR, step 1, and install curb on base.
WARNING
Components of the extractor are heavy and may be awkward to handle. Use
correct lifting procedures, lifting devices, and/or assistance from other personnel
to avoid injury.
5.
Refer to paragraph 3-16 REPAIR, step lm, and install extractor basket.
6.
Connect extractor drain line. Refer to TM 10-3510-209-10.
7.
Place extractor circuit breaker on electrical panel to ON position.
8.
Operate extractor to test. Refer to TM 10-3510-209-10.
NOTE
FOLLOW-ON MAINTENANCE:
Install tarp assembly (TM 10-3510-209-10.)
3-75